Summary for Test 2021-02-05-28-1
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 215211 DEA: 051K6904 EFIS: 0518000230 |
---|---|
DIST-CO-RTE-PM | 05-SB-1,101,154-VAR |
Award Date | 11/19/2020 |
Closeout Date | 11/15/2021 |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 11/13/2020) |
Sample Information
Sample Taken Date | 02/05/2021 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/05/2021 |
Sample type | Quality Control | A brief description of the sample | 1 Quart bottle |
The quantity of what the sample constitutes | 25000 gallons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Tikusis |
Title of sampler | Technical Director | Telephone number of sampler | 707-330-9227 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | 2140690789 |
---|---|---|---|
Batch number | 2140690789 | Mix number | 2140690789 |
Test Details
DIME Sample ID: 2021-02-05-28
DIME Test ID: 2021-02-05-28-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2021-05-28
Test Results
Input Type: Measured
Tester's full name: Spencer Adams
Date of test: 05/28/2021
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 19.6
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.09
Volatile content (ASTM D 2369) 30% max: 23.2
Flash point (ASTM D 3828) more than 180 deg F: 205
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 888
Tack free time, 400 minutes max: 260
General comments (publicly viewable) (Max 1000 characters): Accepted SSD Bond Strength and Tack Free Time based on Vendors Results.
Test was verified on 5/28/2021 ✔