Test 2021-05-16-9-2 (AASHTO T315-16) Summary

Project Information
Project IdentifiersProject ID: 215596
DEA: 061C1604
EFIS: 0621000103
DIST-CO-RTE-PM06-MAD-99-1.5/7.4
Work DescriptionRemove and replace failed pavement on the number 2 lane on both the N and S directions.
Location DescriptionNot set
Sample Information
Sample Taken Date5/16/2021 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/26/2021
Sample typeAcceptance A brief description of the samplePG64-16
The quantity of what the sample constitutes1 of 1 can From where was the sample collectedManufacturer
First name of sampler or witnessed byBrandon Last name of sampler or witnessed byVulcan Tech
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameVulcan Materials - Madera Transportation Laboratory (TL) Numberc039616
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number1
Sublot number1 Tank number
Time of sample HMA SupplierVulcan Materials - Madera
Asphalt Binder SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade TypeNot set HMA Design ID
Test Details
DIME Sample ID: 2021-05-16-9
DIME Test ID: 2021-05-16-9-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-06-07
Test Results

Phase: Original binder
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 05/28/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.133 kPa
Phase Angle (δ) (for the 10 cycles): 89.3 degree
Complex Modulus (G*) (for the 10 measurements): 1.112 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.11 kPa
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specs

Test was verified on 06/07/2021