Summary for Test 2021-05-12-6-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214590
DEA: 043G4744
EFIS: 0412000074
DIST-CO-RTE-PM04-MRN,MRN-580-6.9/7.8,0.0/2.5
Award Date01/14/2021
Closeout DateNot set
Work DescriptionCLEAN AND PAINT STRUCTURAL STEEL BRIDGE.
Location DescriptionCONTRA COSTA AND MARIN COUNTIES IN RICHMOND AND SAN RAFAEL FROM 0.8 MILE WEST OF TOLL PLAZA TO 0.1 MILE EAST OF MAIN STREET
QA Service Level1 (Verified on 02/18/2020)

Sample Information

Sample Taken Date05/12/2021 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing05/26/2021
Sample typeQuality Assurance A brief description of the sample2H Heavy Hex Nut
The quantity of what the sample constitutes700 From where was the sample collectedDistributor
First name of sampler or witnessed byKevin Last name of sampler or witnessed byCarpenter
Title of samplerQA Telephone number of sampler415-608-1742
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUnytite Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB24-028-21 Structure unique identifier
Structure nameSan Rafael Bridge

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)6215131902 Nut Mfg. Lot Number(s)34157-6215131902
Washer Mfg. Lot Number(s) Bolt Specificationn/a
Bolt Length(s) Nut SpecificationA563
Washer Specificationn/a FinishHDG
Diameter/Size1.0" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2021-05-12-6
DIME Test ID: 2021-05-12-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-05-27

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 05/27/2021
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1134157-621513190294476Nut Prooffsaylor

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 5/27/2021