Test 2021-05-17-12-8 (AASHTO T304-11) Summary

Project Information
Project IdentifiersProject ID: 214221
DEA: 081F1424
EFIS: 0815000232
DIST-CO-RTE-PM08-RIV-15-23.9/33.4
Work DescriptionREPLACE INDIVIDUAL PCC SLABS, GRIND PCC PAVEMENT AND UPGRADE GUARDRAIL
Location DescriptionRIVERSIDE COUNTY NEAR LAKE ELSINORE FROM NICHOLS ROAD OVERCROSSING TO 0.2 MILE NORTH OF TEMESCAL CANYON ROAD UNDERCROSSING
Sample Information
Sample Taken Date5/17/2021 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/20/2021
Sample typeVerification A brief description of the samplePSUE 3/4" RHMA-G-SP 0.5% LAS
The quantity of what the sample constitutes4 Bags Of Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byRamy Last name of sampler or witnessed byMekail
Title of sampler Laboratory sample identification0292G-21
The fabricator/manufacturer/facility nameAll American Asphalt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0005
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number106835 A detailed description of where the material sample was collectedBelt Cut at All American Asphalt Corona Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-05-17-12
DIME Test ID: 2021-05-17-12-8
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-05-26
Test Results

What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 05/23/2021
Bulk dry specific gravity: 2.66
Average uncompacted voids:46.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 05/26/2021