Test 2021-05-13-9-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 213746
DEA: 080Q75U4
EFIS: 0817000114
DIST-CO-RTE-PM08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2
Work DescriptionREPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS
Location DescriptionNot set
Sample Information
Sample Taken Date5/13/2021 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/13/2021
Sample typeVerification A brief description of the samplePSUE 3/4" RHMA-G-SP 0.5% LAS
The quantity of what the sample constitutes3 Bags Of Belt Cut Agg., From where was the sample collectedManufacturer
First name of sampler or witnessed byKevin Last name of sampler or witnessed byOluoha
Title of sampler Laboratory sample identification0280G-21
The fabricator/manufacturer/facility nameVulcan Materials-Corona Drum Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0027, 91-33-0073
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number226108 CORD SJR A detailed description of where the material sample was collectedBelt Cut at Vulcan Corona Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-05-13-9
DIME Test ID: 2021-05-13-9-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-05-19
Test Results

What type of gradation is being tested?: Combined Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Input Type: Calculated
Tester's full name: Sebastian Ferrer, Larry Diaz
Date of test: 05/14/2021
Cumulative percent passing the 2 in. sieve:100 %
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:96 %
Cumulative percent passing the 1/2 in. sieve:84 %
Cumulative percent passing the 3/8 in. sieve:70 %
Cumulative percent passing the #4 sieve:26 %
Cumulative percent passing the #8 sieve:19 %
Cumulative percent passing the #16 sieve:13 %
Cumulative percent passing the #30 sieve:9 %
Cumulative percent passing the #50 sieve:5 %
Cumulative percent passing the #100 sieve:3 %
Cumulative percent passing the #200 sieve:2.2 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate Gradation

Test was verified on 05/19/2021