Summary for Test 2021-05-04-9-4

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 215405
DEA: 032G1604
EFIS: 0320000235
DIST-CO-RTE-PM03-YOL-45-0.6/12.9
Award Date02/16/2021
Closeout Date06/30/2021
Work DescriptionCOLD PLANE AC PAVEMENT AND REPLACE WITH HOT MIX ASPHALT.
Location DescriptionYOLO COUNTY NEAR KNIGHTS LANDING FROM SYCAMORE SLOUGH BRIDGE TO YOLO COUNTY LINE ROAD
QA Service Level1 (Verified on 01/18/2021)

Sample Information

Sample Taken Date05/04/2021 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/07/2021
Sample typeAcceptance A brief description of the samplePG64-16
The quantity of what the sample constitutes1 of 1 can From where was the sample collectedManufacturer
First name of sampler or witnessed byTraver Last name of sampler or witnessed byBrewer
Title of samplerTeichert Tech Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Hollwood Transportation Laboratory (TL) Numberc783774
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number2
Sublot number7 Tank number
Time of sample HMA SupplierTeichert Hollwood
Certified Asphalt SupplierMarathon Petroleum Co. LP - Elk Grove CA MultigradeNo
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-04-9
DIME Test ID: 2021-05-04-9-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-05-21

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 05/12/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 44.379 kPa
Phase Angle (δ) (for the 10 cycles): 50.1 degree
Complex Modulus (G*) (for the 10 measurements): 4437.952 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 3405 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 5/21/2021