Test 2021-04-22-1-5 (ASTM B499-14) Summary

Project Information
Project IdentifiersProject ID: 214579
DEA: 010B0904
EFIS: 0100020444
DIST-CO-RTE-PM01-DN-101-8.2/8.7
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionDEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
Sample Information
Sample Taken Date4/22/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/11/2021
Sample typeAcceptance A brief description of the sample1 1/8" A563 Gr DH Nuts
The quantity of what the sample constitutes120 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byMuser
Title of samplerQA Laboratory sample identification
The fabricator/manufacturer/facility nameThompson Metal Fab Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS19-056-21 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)100897555 Nut Mfg. Lot Number(s)432156A
Washer Mfg. Lot Number(s) Bolt SpecificationN/A
Bolt Length(s) Nut SpecificationA563
Washer SpecificationN/A FinishHDG
Diameter/Size1.125 Bolt Mfg. Lot NumberN/A
Rocap Test Requirement(s)No Lubricant Requirements(s)Yes
Test Details
DIME Sample ID: 2021-04-22-1
DIME Test ID: 2021-04-22-1-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-05-20
Test Results

Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 05/12/2021
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 432156A
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: DH N
Size: 1.125 in
Bolt Length: no data
Measurement Average: 4.42 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 05/20/2021