Summary for Test 2021-04-27-10-6
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 214858 DEA: 11424904 EFIS: 1116000094 |
---|---|
DIST-CO-RTE-PM | 11-SD-5,8,15,52,54-Var |
Award Date | 05/13/2020 |
Closeout Date | 09/14/2023 |
Work Description | Install roadside signs. |
Location Description | 11-SD-5, 8, 15, 52, 54, etc.-Var. |
QA Service Level | 1 (Verified on 11/30/2020) |
Sample Information
Sample Taken Date | 04/27/2021 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/27/2021 |
Sample type | Quality Assurance | A brief description of the sample | F1554-55 Anchor Bolt |
The quantity of what the sample constitutes | 146 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Lund |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 385-447-0624 |
Laboratory sample identification | na | Linked DIME Sample ID | na |
The fabricator/manufacturer/facility name | Universal Industrial Sales Inc | Transportation Laboratory (TL) Number | na |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B390-052-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
---|---|---|---|
Heat Number(s) | 1201022732 | Nut Mfg. Lot Number(s) | na |
Washer Mfg. Lot Number(s) | na | Bolt Specification | F1554-55 S1 |
Bolt Length(s) | 4'-2" | Nut Specification | na |
Washer Specification | na | Finish | HGD/Plain |
Diameter/Size | 2" | Bolt Mfg. Lot Number | na |
Rocap Test Requirement(s) | na | Lubricant Requirements(s) | Plain |
Test Details
DIME Sample ID: 2021-04-27-10
DIME Test ID: 2021-04-27-10-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2021-05-20
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 05/07/2021
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 1201022732
Mfg. Lot Number: no data
Finish Coating: Plain and ASTM F2329 - Hot Dip
Product Markings: YELLOW PAINT
Size: 2 in
Bolt Length: 50 in
Measurement Average: 6.38 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/20/2021 ✔