Summary for Test 2021-04-30-5-10

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 215149
DEA: 081G0104
EFIS: 0815000106
DIST-CO-RTE-PM08-SBD-62-124.8/142.0
Award Date10/21/2020
Closeout Date01/18/2022
Work DescriptionPLACE RHMA-G, HMA, STRUCTURAL CONCRETE & ROCK SLOPE PROTECTION.
Location DescriptionSAN BERNARDINO COUNTY AT VARIOUS LOCATIONS FROM 1.8 MILES WEST OF ROUTE 95 TO 0.3 MILE WEST OF PARKER DAM ROAD.
QA Service Level1 (Verified on 01/28/2021)

Sample Information

Sample Taken Date04/30/2021 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/03/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R25, 0.5% LAS
The quantity of what the sample constitutes10 Bags of Agg., 1 Bag of RAP, 2 Bags of Coldfeed From where was the sample collectedManufacturer
First name of sampler or witnessed byKevin Last name of sampler or witnessed byOluoha
Title of sampler Telephone number of sampler
Laboratory sample identification0252A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite - Indio Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0072
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R25 The fabricator/manufacturer designation for the sample
The plant number1535 A detailed description of where the material sample was collectedBelt Cut at Granite Indio Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-30-5
DIME Test ID: 2021-04-30-5-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2021-05-18

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Satish Jain,Juan Leroy
Date of test: 05/07/2021
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 97 %
Cumulative percent passing the 1/2 in. sieve: 86 %
Cumulative percent passing the 3/8 in. sieve: 75 %
Cumulative percent passing the #4 sieve: 45 %
Cumulative percent passing the #8 sieve: 29 %
Cumulative percent passing the #16 sieve: 20 %
Cumulative percent passing the #30 sieve: 13 %
Cumulative percent passing the #50 sieve: 9 %
Cumulative percent passing the #100 sieve: 6 %
Cumulative percent passing the #200 sieve: 3.9 %
General comments (publicly viewable) (Max 1000 characters): Combined RAP/Virgin Aggregate Gradation W/Correlation Factors Applied

Test was verified on 5/18/2021