Test 2021-04-30-5-8 (AASHTO T304-11) Summary

Project Information
Project IdentifiersProject ID: 215149
DEA: 081G0104
EFIS: 0815000106
DIST-CO-RTE-PM08-SBD-62-124.8/142.0
Work DescriptionPLACE RHMA-G, HMA, STRUCTURAL CONCRETE & ROCK SLOPE PROTECTION.
Location DescriptionSAN BERNARDINO COUNTY AT VARIOUS LOCATIONS FROM 1.8 MILES WEST OF ROUTE 95 TO 0.3 MILE WEST OF PARKER DAM ROAD.
Sample Information
Sample Taken Date4/30/2021 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/3/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R25, 0.5% LAS
The quantity of what the sample constitutes10 Bags of Agg., 1 Bag of RAP, 2 Bags of Coldfeed From where was the sample collectedManufacturer
First name of sampler or witnessed byKevin Last name of sampler or witnessed byOluoha
Title of sampler Laboratory sample identification0252A-21
The fabricator/manufacturer/facility nameGranite - Indio Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0072
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R25 The fabricator/manufacturer designation for the sample
The plant number1535 A detailed description of where the material sample was collectedBelt Cut at Granite Indio Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-04-30-5
DIME Test ID: 2021-04-30-5-8
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-05-18
Test Results

What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 05/07/2021
Bulk dry specific gravity: 2.648
Average uncompacted voids:46.9 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 05/18/2021