Summary for Test 2021-04-22-7-1
Test performed: AASHTO T27-14Project Information
Project Identifiers | Project ID: 215405 DEA: 032G1604 EFIS: 0320000235 |
---|---|
DIST-CO-RTE-PM | 03-YOL-45-0.6/12.9 |
Award Date | 02/16/2021 |
Closeout Date | 06/30/2021 |
Work Description | COLD PLANE AC PAVEMENT AND REPLACE WITH HOT MIX ASPHALT. |
Location Description | YOLO COUNTY NEAR KNIGHTS LANDING FROM SYCAMORE SLOUGH BRIDGE TO YOLO COUNTY LINE ROAD |
QA Service Level | 1 (Verified on 01/18/2021) |
Sample Information
Sample Taken Date | 04/22/2021 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/23/2021 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Sam | Last name of sampler or witnessed by | Mosallem |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 21-HMA-0078 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Teichert Hallwood | Transportation Laboratory (TL) Number | C783795 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | NA |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Hallwood plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | 1 | |
Sublot number | 15 | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2021-04-22-7
DIME Test ID: 2021-04-22-7-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-05-07
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 05/03/2021
Cumulative Mass Retained | Cumulative Percent Passing | |||||
---|---|---|---|---|---|---|
5545.9 grams | ||||||
0.0 grams | 100 % | |||||
0.0 grams | 100 % | |||||
20.9 grams | 99.6 % | |||||
705.6 grams | 87.3 % | |||||
1707.2 grams | 69.2 % | |||||
3152.3 grams | 43.2 % | |||||
176.2 grams | 30.4 % | |||||
313.2 grams | 20.5 % | |||||
401.9 grams | 14.1 % | |||||
461.5 grams | 9.8 % | |||||
504.2 grams | 6.7 % | |||||
532.6 grams | 4.65 % | |||||
grams |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/7/2021 ✔