Test 2021-04-01-25-6 (AASHTO T324-14) Summary

The test has been saved successfully.
Project Information
Project IdentifiersProject ID: 212914
DEA: 031E0604
EFIS: 0312000068
DIST-CO-RTE-PM03-YUB-70-15.5/16.5
Work DescriptionSIMMERLY SLOUGH BRIDGE REPLACEMENT BR 16-0019 WITH BR 16-0055.
Location DescriptionNEAR MARYSVILLE, FROM 0.1 MILE NORTH OF BINNEY JUNCTION UNDERPASS TO 0.3 MILE NORTH OF LAURELLEN ROAD, AT SIMMERLY SLOUGH BRIDGE BR 16-0019.
Sample Information
Sample Taken Date4/1/2021 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/1/2021
Sample typeVerification A brief description of the sample3/4" HMA - A w/RAP
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byTeichert Personnel (SAMPLER) Last name of sampler or witnessed by Brad McKeehan (WITNESS)
Title of samplerUnknown Laboratory sample identificationJMF21-020A
The fabricator/manufacturer/facility nameTeichert-Hallwood Drum Plant Transportation Laboratory (TL) NumberC706328
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameNot Applicable
Material Information
Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number JMF Verification ID JMF3513-2021-49
Test Details
DIME Sample ID: 2021-04-01-25
DIME Test ID: 2021-04-01-25-6
Testing Lab: CT D03 - Field Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2021-05-04
Test Results

Input Type: Measured
Tester's full name: Jeff Herbert
Date of test: 04/22/2021
HMA Production: Field Plant Produced
Specified number of passes at 12.7 mm: 15000
Specified number of passes at inflection point: 10000
Type and Amount of Anti-Stripping Additive: N/A
Compaction Method: SGC Cylindrical Specimen
Test Temperature: 122 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 5.78 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 6.89 mm
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average:15000
Impression at specified number of passes average:6 mm
General comments (publicly viewable) (Max 1000 characters): JMF21-020A.

Test was verified on 05/04/2021