Summary for Test 2021-04-22-18-1
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 215163 DEA: 060X3904 EFIS: 0618000061 |
---|---|
DIST-CO-RTE-PM | 06-KIN-43-0.0/3.2 |
Award Date | 11/17/2020 |
Closeout Date | 03/02/2022 |
Work Description | COLD PLANE PAVEMENT, PLACE HMA, RHMA AND TRAFFIC STRIPING. |
Location Description | KINGS COUNTY IN AND NEAR CORCORAN FROM TULARE COUNTY LINE TO 0.1 MILE NORTH OF SANTA FE AVENUE |
QA Service Level | 1 (Verified on 09/14/2020) |
Sample Information
Sample Taken Date | 04/22/2021 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/28/2021 |
Sample type | Acceptance | A brief description of the sample | PG64-16 |
The quantity of what the sample constitutes | 1 of 1 can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Granite | Last name of sampler or witnessed by | Tech |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Granite Coalinga | Transportation Laboratory (TL) Number | c040168 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | Granite Coalinga | |
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-04-22-18
DIME Test ID: 2021-04-22-18-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-05-05
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 05/03/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 170.011 grams
Mass of empty container #2: 168.161 grams
Mass of container #1 before test (m1i): 205.355 grams
Mass of container #2 before test (m2i): 205.039 grams
Mass of container #1 after test (m1f): 205.327 grams
Mass of container #2 after test (m2f): 205.019 grams
Average mass change: -0.067 percent
General comments (publicly viewable) (Max 1000 characters): per standard specifications
Test was verified on 5/5/2021 ✔