Test 2021-04-21-14-5 (AASHTO T96-02r10) Summary

Project Information
Project IdentifiersProject ID: 214848
DEA: 081H3414
EFIS: 0818000172
DIST-CO-RTE-PM08-SBD-210,215,259-Various
Work DescriptionPLACE RHMA-G, COLD PLANE AC AND REPLACE AC SURFACING.
Location DescriptionSAN BERNARDINO COUNTY ON ROUTE 210, 215 AND 259 AT VARIOUS LOCATIONS
Sample Information
Sample Taken Date4/21/2021 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/22/2021
Sample typeVerification A brief description of the sampleJMF 3/4" RHMA-G-SP 0.5% LAS
The quantity of what the sample constitutes4 Bags Of Coldfeed Agg., From where was the sample collectedManufacturer
First name of sampler or witnessed byAAA Corona Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0232G-21
The fabricator/manufacturer/facility nameAll American Asphalt Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0005
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number106835 A detailed description of where the material sample was collectedBelt Cut at All American Corona Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-04-21-14
DIME Test ID: 2021-04-21-14-5
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2021-04-30
Test Results

Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 04/29/2021
Grading designation: C
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4738 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3909 grams
Percent loss after 100 revolutions:5 %
Percent loss after 500 revolutions:22 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/30/2021