Test 2021-04-22-3-1 (ASTM F606-14a) Summary

Project Information
Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
Sample Information
Sample Taken Date4/22/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/29/2021
Sample typeVerification A brief description of the sampleAchor Bolt Assembly
The quantity of what the sample constitutes200 From where was the sample collectedManufacturer
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameA and M Nut and Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-126-21 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s) Nut Mfg. Lot Number(s)33576-201466
Washer Mfg. Lot Number(s)D9568 Bolt SpecificationASTM F1554 Grade 55
Bolt Length(s)15" with 2" hook Nut SpecificationASTM A194 HHN Grade 2H
Washer SpecificationASTM F436 M/G FinishHDG
Diameter/Size3/4" Bolt Mfg. Lot Number3085620
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2021-04-22-3
DIME Test ID: 2021-04-22-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-05-06
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/29/2021
UTM:400kip
Temperature:72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1233576-20146658664Nut Proofbewing

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 05/06/2021