Summary for Test 2021-02-12-11-1

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 215148
DEA: 081E8404
EFIS: 0814000113
DIST-CO-RTE-PM08-RIV,SBD-62-R6.7/9.2,0.0/15.1,29.3/33.6
Award Date12/11/2020
Closeout Date03/01/2023
Work DescriptionREPLACE ROADWAY WITH RHMA-G AND HMA.
Location DescriptionIN RIVERSIDE AND SAN BERNARDINO COUNTIES IN AND NEAR YUCCA VALLEY AND IN TWENTYNINE PALMS FROM 0.2 MILE NORTH OF INDIAN CANYON DRIVE TO 0.6 MILE WEST OF UTAH TRAIL
QA Service Level1 (Verified on 03/18/2021)

Sample Information

Sample Taken Date02/12/2021 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/15/2021
Sample typeQuality Control A brief description of the sample3/4" HMA Type A
The quantity of what the sample constitutes JMF renewal 16 boxs, 3 bags of each bin, 1 bag of belt cut From where was the sample collectedSupplier
First name of sampler or witnessed byJohn Last name of sampler or witnessed byLara
Title of samplerQC Manager Telephone number of sampler909-991-2176
Laboratory sample identification21-1096, 21-1097 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMatich-Lytle Creek Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2021-02-12-11
DIME Test ID: 2021-02-12-11-1
Testing Lab: Aragon Geotechnical, Incorporated
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-05-04

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Water
Input Type: Calculated
Tester's full name: Fernando Aragon
Date of test: 02/16/2021
Specific Gravity for Sample 1: 2.479
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/4/2021