Summary for Test 2021-04-26-10-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 214795 DEA: 030H3424 EFIS: 0317000153 |
---|---|
DIST-CO-RTE-PM | 03-SAC-99-22.6 |
Award Date | 11/13/2020 |
Closeout Date | 03/03/2022 |
Work Description | REPLACE BRIDGE DECK WITH PRESTRESSED CONCRETE BOX GIRDER. |
Location Description | SACRAMENTO COUNTY IN SACRAMENTO AT 21ST AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 03/12/2020) |
Sample Information
Sample Taken Date | 04/26/2021 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/27/2021 |
Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 2 6x12 concrete cylinders | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Mark Patrick | Last name of sampler or witnessed by | Baddu |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Con-Fab California, LLC | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | VER-95LV |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 3331 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Bed 2, 2nd Truck | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-04-26-10
DIME Test ID: 2021-04-26-10-1
Testing Lab: Con-Fab California Corporation - Lathrop
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-04-27
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Ferdinand Rosal
Date of test: 04/27/2021
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 148500 lb
Maximum load on cylinder 2: 149900 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 0 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5280 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/27/2021 ✔