Test 2021-04-07-27-1 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 214190
DEA: 024G41U4
EFIS: 0218000047
DIST-CO-RTE-PM02-SIS,SIS-5-Var
Work DescriptionREPLACE REINFORCED CONCRETE BRIDGES & CONSTRUCT RETAINING WALL.
Location DescriptionSHASTA AND SISKIYOU COUNTIES ABOUT 7 MILES NORTH OF POLLARD FLAT FROM 0.8 MILE SOUTH TO 0.7 MILE NORTH OF SIMS ROAD UNDERCROSSING AND FROM 0.6 MILE SOUTH OF CASTLE CRAGS DRIVE UNDERCROSSING TO 0.2 MILE SOUTH OF SOUTH DUNSMUIR UNDERCROSSING
Sample Information
Sample Taken Date4/7/2021 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/7/2021
Sample typeAcceptance A brief description of the sampleCoarse PCC Aggregate (3/8-inch x No. 8)
The quantity of what the sample constitutesUndefined From where was the sample collectedSource
First name of sampler or witnessed byColt Last name of sampler or witnessed bySweeny
Title of samplerTET Laboratory sample identificationD78758
The fabricator/manufacturer/facility nameJF Shea Construction, Shasta Redi-Mix, Redding, CA Transportation Laboratory (TL) Number002571
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)Undefined
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUndefined Lot number
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2021-04-07-27
DIME Test ID: 2021-04-07-27-1
Testing Lab: CT D02 - North Region Materials Lab
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2021-05-20
Test Results

What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Measured
Tester's full name: Karen Dorado
Date of test: 04/08/2021
Cumulative mass retained on the 1/2 in. sieve: 0 grams
Cumulative mass retained on the 3/8 in. sieve: 13 grams
Cumulative mass retained on the #4 sieve: 897 grams
Cumulative mass retained on the #8 sieve: 1014 grams
Cumulative mass retained on the pan: 1019 grams
Mass of all aggregate: 1019 grams
Cumulative percent passing the 1/2 in. sieve:100 %
Cumulative percent passing the 3/8 in. sieve:99 %
Cumulative percent passing the #4 sieve:12 %
Cumulative percent passing the #8 sieve:0 %
General comments (publicly viewable) (Max 1000 characters): Unknown mix design, x-value is undefined.

Test was verified on 05/20/2021