Summary for Test 2021-03-18-1-3
Test performed: AASHTO T228-09r13Project Information
Project Identifiers | Project ID: 55555 DEA: AMRL EFIS: AMRL |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for AASHTO Materials Reference Laboratory (AMRL). |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/18/2021 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/18/2021 |
Sample type | Proficiency | A brief description of the sample | 263(A) PSP VISCOSITY GRADED |
The quantity of what the sample constitutes | 1 of 1 can | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | AASHTO resource | Last name of sampler or witnessed by | AASHTO resource |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | AASHTO resource PSP | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-22 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | PNAC LLC - Fernley NV | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-03-18-1
DIME Test ID: 2021-03-18-1-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T228-09r13: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)
Test Release Date: 2021-04-30
Test Results
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 04/13/2021
Mass of Pycnometer (plus Stopper): 39.946 grams
Mass of pycnometer filled with water: 65.690 grams
Mass of pycnomter partially filled with asphalt: 57.478 grams
Mass of pycnometer plus asphalt plus water: 66.388 grams
Test Temperature: 25.0 C
Density of Water at Test Temperature: 997.0 kg/m^3
Specific Gravity: 1.041
Density: 1038 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/30/2021 ✔