Summary for Test 2021-04-07-6-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 215673
DEA: 031J9204
EFIS: 0321000148
DIST-CO-RTE-PM03-BUT-70-15.43/15.43, 15.43
Award Date03/17/2021
Closeout Date01/18/2022
Work DescriptionButte 70 Girders Repair - Major Damage Restoration
Location DescriptionNot set
QA Service Level1 (Verified on 05/17/2021)

Sample Information

Sample Taken Date04/07/2021 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/09/2021
Sample typeQuality Assurance A brief description of the sampleD250L Bar Lock Coupler
The quantity of what the sample constitutes500 couplers From where was the sample collectedFabricator
First name of sampler or witnessed byJustin Last name of sampler or witnessed byWood
Title of samplerRE Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameC and N Rebar Yard Transportation Laboratory (TL) NumberC0001
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelD250L Bar Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)MM20102405 186361 Rebar Heat Number(s)489820
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-04-07-6
DIME Test ID: 2021-04-07-6-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-04-09

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/09/2021
UTM: 2000kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 11/36mm101.5614977796011Service Splicebewing

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.