Test 2021-03-19-3-7 (ASTM D4791-10) Summary

Project Information
Project IdentifiersProject ID: 215150
DEA: 120P0304
EFIS: 1215000024
DIST-CO-RTE-PM12-ORA-74-11.5/16.6
Work DescriptionPLACE HIGH FRICTION SURFACE TREATMENT, HMA & MIDWEST GUARDRAIL SYSTEM.
Location DescriptionORANGE COUNTY NEAR SAN JUAN CAPISTRANO FROM 1.0 MILE WEST OF SAN JUAN HOT SPRINGS ROAD TO ORANGE COUNTY LINE
Sample Information
Sample Taken Date3/19/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/22/2021
Sample typeVerification A brief description of the sampleJMF 3/4" WMA-A-SP R25, 0.25% Evotherm
The quantity of what the sample constitutes3 Bags of Coldfeed Aggregate , 1 Bag of RAP From where was the sample collectedDistributor
First name of sampler or witnessed byRJ Noble Orange Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0167A-21
The fabricator/manufacturer/facility nameRJ Noble Orange Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0014, 91-33-0039
The fabricator's/manufacturer's product name for the sample3/4 WMA-A-SP R25 The fabricator/manufacturer designation for the sample
The plant number36R2508SPWEC A detailed description of where the material sample was collectedBelt Cut at RJ Noble Orange Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-03-19-3
DIME Test ID: 2021-03-19-3-7
Testing Lab: CT - Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2021-04-09
Test Results

Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Michael Magana
Date of test: 04/01/2021
Weighted percentage of particles (by mass) that were flat and elongated:1 %
Weighted percentage of particles (by mass) that were not flat and elongated:99 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/09/2021