Test 2021-03-24-20-6 (AASHTO T48-18) Summary

Project Information
Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date3/24/2021 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/24/2021
Sample typeQuality Control A brief description of the sampleCOC asphalt binder
The quantity of what the sample constitutes1 of 2 split sample From where was the sample collectedManufacturer
First name of sampler or witnessed byLuis Last name of sampler or witnessed byTorres
Title of samplerCOC Program Laboratory sample identification
The fabricator/manufacturer/facility nameWestern Emulsions Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number25K3
Time of sample8:00AM HMA Supplier
Asphalt Binder SupplierValero Coolidge - Coolidge AZ MultigradeNot set
Multigrade TypeNot set HMA Design ID
Test Details
DIME Sample ID: 2021-03-24-20
DIME Test ID: 2021-03-24-20-6
Testing Lab: Veleroo - Coolidge
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2021-04-05
Test Results

Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Calculated
Tester's full name: Binder Lab Tester 1
Date of test: 03/24/2021
Observed Flash Point: 316 C
Ambient Barometric Pressure: 28.4 mmHg
Cleveland Open-Cup Flash Point in Celsius: 317 C
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/05/2021