Summary for Test 2020-10-29-29-5

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 214515
DEA: 024F6004
EFIS: 0213000012
DIST-CO-RTE-PM02-SIS,TRI-36,96,299-VAR
Award Date01/14/2020
Closeout Date08/24/2022
Work DescriptionBRIDGE DECK REPAIR, POLYESTER OVERLAY AND RAIL REPLACEMENT.
Location DescriptionSISKIYOU AND TRINITY COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 01/22/2020)

Sample Information

Sample Taken Date10/29/2020 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/29/2020
Sample typeVerification A brief description of the sample1/2-inch Type A Untreated Virgin Aggreagte
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byNRML Last name of sampler or witnessed byRedding
Title of sampler Telephone number of sampler
Laboratory sample identificationD78689F Linked DIME Sample ID
The fabricator/manufacturer/facility nameMercer-Fraser Company, Willow Creek Plant Transportation Laboratory (TL) Number853340
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-12-0007
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedLab-Batched from Sized Untreated Aggregate Stockpiles
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberJMF 20-11-S3 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-10-29-29
DIME Test ID: 2020-10-29-29-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-04-02

Test Results


Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 12/30/2020
Mass of saturated surface dry sample (before pycnometer) (S): 499.2 grams
Mass of the pycnometer with water and aggregate (C): 971.1 grams
Mass of the pycnometer with water (B): 649.1 grams
Mass of the oven dried sample (before pycnometer) (A): 492.7 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 499.2 grams
Mass of the oven dry aggregate (for absorption) (A): 492.7 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.780
Bulk specific gravity (SSD Basis): 2.817
Apparent specific gravity: 2.886
Absorption: 1.3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/2/2021