Summary for Test 2021-03-25-3-3

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 215063
DEA: 032F5704
EFIS: 0300020615
DIST-CO-RTE-PM03-PLA-80-46.3/63.5
Award Date09/23/2020
Closeout Date08/11/2023
Work DescriptionReplace 4 Bridges (OC) on Highway 80 from Crystal Springs to Cisco Grove (Baxter, Drum Forebay)
Location DescriptionNot set
QA Service Level1 (Verified on 11/16/2020)

Sample Information

Sample Taken Date03/25/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/29/2021
Sample typeQuality Assurance A brief description of the sample#9 BarSplice 10A T-Heads
The quantity of what the sample constitutes44 T-Heads From where was the sample collectedFabricator
First name of sampler or witnessed bySamuel Last name of sampler or witnessed bySoto
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCamblin Steel Service Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4101383 Head Manufacturer Lot Number(s)A204230 Grip-Twist Male, A202389 Grip-Twist D
Rebar Size#9 Headed Bar Model Name10A
Size of HeadFull Size - 9x Head Connection TypeTaper Threaded
Head ShapeCircular Rebar ManufacturerCMC
Head ManufacturerBarSplice Products Head FabricatorCamblin Steel
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2021-03-25-3
DIME Test ID: 2021-03-25-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-03-30

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 03/29/2021
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
1119989599895Brittel Break At Crimpfsaylor

General comments (publicly viewable) (Max 1000 characters): Brittel Break At Crimp
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 3/30/2021