Summary for Test 2015-05-22-3-4
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 209453 DEA: 080J8504 EFIS: 0800000324 |
---|---|
DIST-CO-RTE-PM | 08-SBD-138-R24.1 |
Award Date | 07/01/2014 |
Closeout Date | 07/05/2017 |
Work Description | REPLACE EXISTING BRIDGE. |
Location Description | SAN BERNARDINO COUNTY IN AND NEAR HESPERIA AT HORSETHIEF CREEK BRDIGE |
QA Service Level | 1 (Verified on 04/16/2014) |
Sample Information
Sample Taken Date | 05/22/2015 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/27/2015 |
Sample type | Quality Control | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | G | Last name of sampler or witnessed by | PAREDES |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 901-22 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | JOB | Transportation Laboratory (TL) Number | 15222 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | HORSETHEIF CREEK BRIDGE 54 1271 |
Structure name | BENT 2 AND 3 AT SPLICE AREAS |
Material Information
Material Type | Concrete | The concrete mix design number | HG78547A |
---|---|---|---|
The truck number from where the sample was collected | 174 | The batch plant ticket number from where the sample was collected | 822026 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | CHUTE | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-05-22-3
DIME Test ID: 2015-05-22-3-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-07-01
Test Results
Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 07/01/2015
Average diameter of cylinder 1: 6.01 in
Maximum load on cylinder 1: 151150 lb
Type of fracture pattern of cylinder 1: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 40 days
Cross sectional area of cylinder 1: 28.37 in^2
Compressive strength of cylinder (to nearest 10 psi): 5330 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/1/2015 ✔