Test 2015-06-22-4-1 (ASTM C39-10) Summary

Project Information
Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
Sample Information
Sample Taken Date6/22/2015 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/26/2015
Sample typeAcceptance A brief description of the sampleFrame 1b deck H8 to H10
The quantity of what the sample constitutes257 yd From where was the sample collectedJob Site
First name of sampler or witnessed byNana Last name of sampler or witnessed byBudu
Title of samplerTE Civil Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameCentral Concrete Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier9 day break
Structure nameEB Onramp
Material Information
Material TypeConcrete The concrete mix design numberD101C5E1
The truck number from where the sample was collected1198 The batch plant ticket number from where the sample was collected18039091
Concrete batch plant12 The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedat pump Where the material sample would have been placed if not sampled1b deck
From Lot No.Not set Bag Lot No.Not set
Test Details
DIME Sample ID: 2015-06-22-4
DIME Test ID: 2015-06-22-4-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-07-01
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bang
Date of test: 07/01/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.03 in
Average diameter of cylinder 2: 6.03 in
Maximum load on cylinder 1: 123063 lb
Maximum load on cylinder 2: 121878 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 9 days
Cross sectional area of cylinder 1: 28.56 in^2
Cross sectional area of cylinder 2: 28.56 in^2
Compressive strength of cylinder 1: 4308.9 psi
Compressive strength of cylinder 2: 4267.4 psi
Compressive strength (to nearest 10 psi):4290 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 07/01/2015