Summary for Test 2021-02-01-12-10

Test performed: ASTM C266-15

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/01/2021 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/01/2021
Sample typeProficiency A brief description of the samplePortland Cement
The quantity of what the sample constitutes1 sample From where was the sample collectedManufacturer
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM218219 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCCRL Portland 219 Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandCCRL
MillCCRL Type of Cementitious MaterialType II Cement

Test Details

DIME Sample ID: 2021-02-01-12
DIME Test ID: 2021-02-01-12-10
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C266-15: Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles
Test Release Date: 2021-03-18

Test Results


Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 03/10/2021
Initial time of setting: 194 min
Final time of setting: 371 min
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/18/2021