Test 2021-02-19-2-1 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 212085
DEA: 07296604
EFIS: 0713000057
DIST-CO-RTE-PM07-LA-10-14.0/19.0
Work DescriptionPAINT AND REHABILITATE BRIDGE - (STRAIN (PAINT AND INSTALL CATWALK)
Location DescriptionIN THE CITY OF LOS ANGELES, AT SANTA MONICA VIADUCT (BR. NO. 53-1301). PAINT AND REHABILITATE BRIDGE
Sample Information
Sample Taken Date2/19/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/19/2021
Sample typeVerification A brief description of the sampleA325 Fastener Assembly
The quantity of what the sample constitutes1500 From where was the sample collectedDistributor
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Laboratory sample identification
The fabricator/manufacturer/facility namePage Industrial Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-048-21 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s) Nut Mfg. Lot Number(s)33631-190839
Washer Mfg. Lot Number(s)D9458 Bolt SpecificationASTM A325TC
Bolt Length(s)1 3/4" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishMechanical Galvanized
Diameter/Size3/4" Bolt Mfg. Lot Number33539-100203733
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2021-02-19-2
DIME Test ID: 2021-02-19-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-03-16
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 03/12/2021
UTM:450kip
Temperature:72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A33631-19083952791Proof Loadfsaylor

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 03/16/2021