Summary for Test 2021-03-04-3-8

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 214686
DEA: 030H4004
EFIS: 0315000164
DIST-CO-RTE-PM03-NEV,PLA,YOL-80-VAR
Award Date04/15/2020
Closeout Date08/11/2023
Work DescriptionREPLACE ELECTRICAL SIGNS & INSTALL FIBER OPTIC COMMUNICATION LINES.
Location DescriptionNEVADA, PLACER AND YOLO COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date03/04/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/04/2021
Sample typeQuality Assurance A brief description of the sample7/8 x 26 A449 all thread rod HDG (Anchor Bolt Hardware)
The quantity of what the sample constitutes115 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler1-385-447-0624
Laboratory sample identificationna Linked DIME Sample IDna
The fabricator/manufacturer/facility nameUniversal Industrial Sales Inc Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-027-01 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)10537410 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt SpecificationA449
Bolt Length(s)26" Nut Specificationna
Washer Specificationna FinishHDG
Diameter/Size7/8" Bolt Mfg. Lot Number33172
Rocap Test Requirement(s)na Lubricant Requirements(s)na

Test Details

DIME Sample ID: 2021-03-04-3
DIME Test ID: 2021-03-04-3-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2021-03-11

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 03/10/2021
UTM: 67kip
Temperature: 72 f
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1203310.4990.19611424513105620.8fsaylor

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 3/11/2021