Summary for Test 2015-06-11-2-1

Test performed: CTM 521-November 2014

Project Information

Project IdentifiersProject ID: 7409
DEA: 07245403
EFIS: 0700000431
DIST-CO-RTE-PM07-LA-10-31.1/32.3
Award Date02/29/2012
Closeout Date10/27/2016
Work DescriptionConstruct Connector between I-10 and I-605 (Design Build Project) LA-10-31.1/32.3, LA-605-R20.2/20.6
Location Description10 & 605 IC
QA Service Level1 (Verified on 03/14/2013)

Sample Information

Sample Taken Date06/11/2015 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/15/2015
Sample typeQuality Control A brief description of the sample6x12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byoscar Last name of sampler or witnessed byrodriguez
Title of samplerasr Telephone number of samplerUnknown
Laboratory sample identification854-22 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namejob Transportation Laboratory (TL) Number60522
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier10 605 interchange
Structure namehinge b bottom seat

Material Information

Material TypeConcrete The concrete mix design numbers75099
The truck number from where the sample was collected391 The batch plant ticket number from where the sample was collected202720
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedtruck Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2015-06-11-2
DIME Test ID: 2015-06-11-2-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-06-22

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 06/22/2015
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 112510 lb
Maximum load on cylinder 2: 121720 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 11 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 3965.8 psi
Compressive strength of cylinder 2: 4290.4 psi
Compressive strength (to nearest 10 psi): 4130 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/22/2015