Summary for Test 2021-02-24-16-1

Test performed: CTM 226-July 2010

Project Information

Project IdentifiersProject ID: 214756
DEA: 050N7AU4
EFIS: 0520000030
DIST-CO-RTE-PM05-SB-101-1.4/4.8
Award DateNot set
Closeout Date09/27/2022
Work DescriptionSegment 4A - Carpinteria: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, epoxy coated rebar, precast box culverts, precast RCP.
Location DescriptionCARPINTERIA FROM 0.2 MILE SOUTH OF BAILARD AVENUE OVERCROSSING TO 0.7 MILE SOUTH OF SOUTH PADARO LANE
QA Service Level1 (Verified on 03/09/2020)

Sample Information

Sample Taken Date02/24/2021 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/25/2021
Sample typeQuality Control A brief description of the sample1 X 4 Concrete Aggregate
The quantity of what the sample constitutes100 cy From where was the sample collectedSource
First name of sampler or witnessed byScott Last name of sampler or witnessed byPowell
Title of samplerQC Technician Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHanson Goleta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameSound Wall 4B Pile Cap

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-42-0003
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt cut of Coarse and Fine Aggregate at Source
Where the material sample would have been placed if not sampledSound Wall 4B Pile Cap Primary Aggregate Nominal Size1 inch
The concrete mix design number63511N0P Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-02-24-16
DIME Test ID: 2021-02-24-16-1
Testing Lab: Sequoia Consultants
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2021-03-08

Test Results


Input Type: Calculated
Tester's full name: Leo Santamaria
Date of test: 02/25/2021
Wet weight of the sample: 521.4000000000 grams
Dry weight of the sample: 491.9000000000 grams
Weight of water in sample: 29.5000000000 grams
Percent moisture: 6.0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/8/2021