Summary for Test 2020-07-23-48-6

Test performed: CTM 204-June 2010

Project Information

Project IdentifiersProject ID: 214618
DEA: 033F99U4
EFIS: 0319000311
DIST-CO-RTE-PM03-SUT-99-39.2/41.4
Award Date05/15/2020
Closeout Date12/13/2023
Work DescriptionWIDEN RDWY, HMA, CRCP, WATER LINE, SIGNALS, & LIGHTING SYSTEM.
Location DescriptionSUTTER COUNTY IN AND NEAR LIVE OAK FROM 0.1 MILE SOUTH OF COLEMAN AVENUE TO NEVADA STREET (NORTH INTERSECTION)
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date07/23/2020 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/24/2020
Sample typeVerification A brief description of the sampleVirgin Aggregate 1/2-inch, Type A HMA/w RAP
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byM. Last name of sampler or witnessed byChittenden (WITNESS)
Title of samplerDSG Personnel Telephone number of sampler
Laboratory sample identificationJMF20-032 Linked DIME Sample ID
The fabricator/manufacturer/facility nameDeSilva Gates Aggregates-Marysville Transportation Laboratory (TL) NumberC723296
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-58-0001::WESTERN AGGREGATES
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-23-48
DIME Test ID: 2020-07-23-48-6
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Test Release Date: 2021-03-03

Test Results


The test method used?: Plastic Index
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 07/30/2020
Liquid Limit (LL): 0 %
Plastic Limit (PL): 0 %
Plastic Index(PI): NP
General comments (publicly viewable) (Max 1000 characters): JMF20-032.

Test was verified on 3/3/2021