Test 2020-08-10-46-9 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 214618
DEA: 033F99U4
EFIS: 0319000311
DIST-CO-RTE-PM03-SUT-99-39.2/41.4
Work DescriptionWIDEN RDWY, HMA, CRCP, WATER LINE, SIGNALS, & LIGHTING SYSTEM.
Location DescriptionSUTTER COUNTY IN AND NEAR LIVE OAK FROM 0.1 MILE SOUTH OF COLEMAN AVENUE TO NEVADA STREET (NORTH INTERSECTION)
Sample Information
Sample Taken Date8/10/2020 Sample Unique Key46
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/11/2021
Sample typeVerification A brief description of the sampleVirgin Aggregate 3/4 RHMA-G
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byBrad Last name of sampler or witnessed byMckeehan (WITNESS)
Title of samplerDGS Personnel Laboratory sample identificationJMF20-030B
The fabricator/manufacturer/facility nameDSG Aggregates - Marysville Transportation Laboratory (TL) NumberC 779832
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-58-0001
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID JMF3513-2021-27
Test Details
DIME Sample ID: 2020-08-10-46
DIME Test ID: 2020-08-10-46-9
Testing Lab: CT D03 - North Region Materials Lab
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-02-25
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Input Type: Calculated
Tester's full name: Thom Stinnett
Date of test: 08/11/2020
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:97 %
Cumulative percent passing the 1/2 in. sieve:79 %
Cumulative percent passing the 3/8 in. sieve:67 %
Cumulative percent passing the #4 sieve:29 %
Cumulative percent passing the #8 sieve:16 %
Cumulative percent passing the #16 sieve:10 %
Cumulative percent passing the #30 sieve:7 %
Cumulative percent passing the #50 sieve:5 %
Cumulative percent passing the #100 sieve:4 %
Cumulative percent passing the #200 sieve:2.7 %
General comments (publicly viewable) (Max 1000 characters): JMF20-030B. Test date estimated.

Test was verified on 02/25/2021