Summary for Test 2020-06-04-41-4
Test performed: AASHTO T304-11Project Information
Project Identifiers | Project ID: 212535 DEA: 031A9204 EFIS: 0300020608 |
---|---|
DIST-CO-RTE-PM | 03-SUT-20-5-11.3 |
Award Date | 06/11/2019 |
Closeout Date | 12/01/2021 |
Work Description | SUTTER BYPASS WIDENING AND REHAB |
Location Description | NEAR YUBA CITY FROM SUTTER BYPASS TO 0.1 MILE WEST OF LYTLE ROAD. |
QA Service Level | 1 (Verified on 07/23/2018) |
Sample Information
Sample Taken Date | 06/04/2020 | Sample Unique Key | 41 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/05/2020 |
Sample type | Verification | A brief description of the sample | 3/4 " RHMA-G |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brad | Last name of sampler or witnessed by | McKeehan (WITNESS) |
Title of sampler | KRC Personnel | Telephone number of sampler | |
Laboratory sample identification | JMF20-023B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | KRC Hallwood | Transportation Laboratory (TL) Number | C693829 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-58-0002 (Hallwood Plant) |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Cold Feed | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-04-41
DIME Test ID: 2020-06-04-41-4
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-02-23
Test Results
What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Thom Stinnett
Date of test: 06/15/2020
Bulk dry specific gravity: 2.683
Average uncompacted voids: 46.6 %
General comments (publicly viewable) (Max 1000 characters): JMF20-023B. Test date estimated.
Test was verified on 2/23/2021 ✔