Test 2020-11-13-19-7 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date11/13/2020 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/3/2021
Sample typeVerification A brief description of the sampleBagged aggregate - Drum Plant
The quantity of what the sample constitutesBags of aggregate From where was the sample collectedSupplier
First name of sampler or witnessed byMark Last name of sampler or witnessed byDaniels
Title of sampler Laboratory sample identification21-JMFPP-0017
The fabricator/manufacturer/facility nameGranite Construction Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-39-0002
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID JMF3513-2021-22
Test Details
DIME Sample ID: 2020-11-13-19
DIME Test ID: 2020-11-13-19-7
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-02-22
Test Results

Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 02/11/2021
Mass of saturated surface dry sample (before pycnometer) (S): 500.2 grams
Mass of the pycnometer with water and aggregate (C): 987 grams
Mass of the pycnometer with water (B): 678 grams
Mass of the oven dried sample (before pycnometer) (A): 489.5 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.2 grams
Mass of the oven dry aggregate (for absorption) (A): 489.5 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.560
Bulk specific gravity (SSD Basis):2.616
Apparent specific gravity:2.712
Absorption:2.2 %
General comments (publicly viewable) (Max 1000 characters): Bulk specific gravity (SSD) of fine aggregate, Bulk specific gravity of fine aggregate, Apparent specific gravity of fine aggregate, Apparent specific gravity of supplemental fines, Absorption of fine aggregate

Test was verified on 02/22/2021