Test 2021-02-12-3-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 214909
DEA: 120N8604
EFIS: 1214000123
DIST-CO-RTE-PM12-ORA-73-23.7/24.1
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGE & RETAINING WALL; & PLACE HMA.
Location DescriptionORANGE COUNTY IN NEWPORT BEACH FROM 0.3 MILE NORTH OF BISON AVENUE TO 0.3 MILE SOUTH OF UNIVERSITY DRIVE
Sample Information
Sample Taken Date2/12/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/16/2021
Sample typeQuality Assurance A brief description of the sampleWelded Rebar Hoops
The quantity of what the sample constitutes120 From where was the sample collectedFabricator
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameCMC Etiwanda Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-044-21 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4105000
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#5
Diameter of Hoop4'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Arizona
Welding CompanyCMC Etiwanda Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2021-02-12-3
DIME Test ID: 2021-02-12-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-02-17
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 02/17/2021
UTM:400kip
Temperature:72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1215/16mm0.3129478.8095093OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 02/17/2021