Summary for Test 2015-05-15-2-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 209153 DEA: 043A8704 EFIS: 0400000967 |
---|---|
DIST-CO-RTE-PM | 04-CC-680-22.7/24.8 |
Award Date | 04/16/2014 |
Closeout Date | 09/28/2016 |
Work Description | RETROFIT BRIDGE, REPLACE BRIDGE, AND CONSTRUCT EMERGENCY ACCESS LANE. |
Location Description | CONTRA COSTA COUNTY IN AND NEAR MARTINEZ FROM ARTHUR ROAD UNDERCROSSING TO 0.5 MILE NORTH OF MOCOCO OVERHEAD |
QA Service Level | 1 (Verified on 02/06/2014) |
Sample Information
Sample Taken Date | 05/15/2015 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/26/2015 |
Sample type | Quality Control | A brief description of the sample | concrete |
The quantity of what the sample constitutes | concrete cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | ED | Last name of sampler or witnessed by | li |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | 207208 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | 1519161 |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | Unknown |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | Back of Truck | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-05-15-2
DIME Test ID: 2015-05-15-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-06-12
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mullins
Date of test: 06/12/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 152907 lb
Maximum load on cylinder 2: 154786 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 5408.8 psi
Compressive strength of cylinder 2: 5456.0 psi
Compressive strength (to nearest 10 psi): 5430 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 6/12/2015 ✔