Summary for Test 2020-07-13-53-9

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214802
DEA: 031G7004
EFIS: 0319000135
DIST-CO-RTE-PM03-SUT-99-28.0/30.6
Award Date05/18/2020
Closeout Date03/16/2021
Work DescriptionCOLD PLANE AC PAVEMENT, RHMA OVERLAY, & INDUCTIVE LOOP DETECTORS.
Location DescriptionSUTTER COUNTY IN AND NEAR YUBA CITY FROM 0.1 MILE NORTH OF SMITH ROAD TO ROUTE 20
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date07/13/2020 Sample Unique Key53
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/14/2020
Sample typeVerification A brief description of the sample3/4" RHMA-G
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byDSG Personnel Last name of sampler or witnessed byDSG Personnel
Title of sampler Telephone number of sampler
Laboratory sample identificationJMF20-030 Linked DIME Sample ID2020-07-22-57
The fabricator/manufacturer/facility nameDeSilva Gates Aggregates-Marysville Transportation Laboratory (TL) Numberc723256
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-58-0001::WESTERN AGGREGATES
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-13-53
DIME Test ID: 2020-07-13-53-9
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-02-11

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Thomas Stinnett
Date of test: 07/14/2020
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 99 %
Cumulative percent passing the 1/2 in. sieve: 81 %
Cumulative percent passing the 3/8 in. sieve: 68 %
Cumulative percent passing the #4 sieve: 31 %
Cumulative percent passing the #8 sieve: 17 %
Cumulative percent passing the #16 sieve: 10 %
Cumulative percent passing the #30 sieve: 7 %
Cumulative percent passing the #50 sieve: 5 %
Cumulative percent passing the #100 sieve: 4 %
Cumulative percent passing the #200 sieve: 2.7 %
General comments (publicly viewable) (Max 1000 characters): JMF20-030. Test date estimated.

Test was verified on 2/11/2021