Summary for Test 2015-04-27-11-2

Test performed: CTM 521-November 2014

Project Information

Project IdentifiersProject ID: 3959
DEA: 072159C4
EFIS: 0700000339
DIST-CO-RTE-PM07-LA-5-001.8/003.0
Award Date08/19/2011
Closeout Date08/16/2018
Work DescriptionCARMENITA INTERCHANGE IMPROVEMENT
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS AND NORWALK FROM ALONDRA BOULEVARD OVERCROSSING TO SHOEMAKER AVENUE OVERCROSSING
QA Service Level1 (Verified on 05/01/2012)

Sample Information

Sample Taken Date04/27/2015 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/01/2015
Sample typeQuality Control A brief description of the sampleconcrete Cylinders
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed bycalvin Last name of sampler or witnessed bydao
Title of samplerTEC Telephone number of samplerUnknown
Laboratory sample identification833-2A Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namesite Transportation Laboratory (TL) Numberset 2a
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberSM40325
The truck number from where the sample was collected354 The batch plant ticket number from where the sample was collected162405
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedpour 160 set 2 right deck from span 7 to 9 Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2015-04-27-11
DIME Test ID: 2015-04-27-11-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-06-08

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 06/08/2015
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 127120 lb
Maximum load on cylinder 2: 130890 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 42 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 4480.8 psi
Compressive strength of cylinder 2: 4613.7 psi
Compressive strength (to nearest 10 psi): 4550 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/8/2015