Summary for Test 2021-02-06-1-3
Test performed: AASHTO T315-16Project Information
Project Identifiers | Project ID: 214700 DEA: 030F2804 EFIS: 0312000069 |
---|---|
DIST-CO-RTE-PM | 03-SAC-99-7.1/9.4 |
Award Date | 01/21/2021 |
Closeout Date | 08/21/2023 |
Work Description | Dillard Overcrossing and McConnel Overhead |
Location Description | Hwy 99, Elk Grove, CA |
QA Service Level | 1 (Verified on 04/20/2020) |
Sample Information
Sample Taken Date | 02/06/2021 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/08/2021 |
Sample type | Acceptance | A brief description of the sample | TEST Asphalt Binder |
The quantity of what the sample constitutes | 2 cans, #1 Test | From where was the sample collected | Source |
First name of sampler or witnessed by | Tyler | Last name of sampler or witnessed by | Christianson |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | 790479 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | Lot number | 1 | |
Sublot number | 1 | Tank number | |
Time of sample | HMA Supplier | Not set | |
Certified Asphalt Supplier | Not set | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-02-06-1
DIME Test ID: 2021-02-06-1-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-02-09
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 02/09/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.238 kPa
Phase Angle (δ) (for the 10 cycles): 84.4 degree
Complex Modulus (G*) (for the 10 measurements): 1.981 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.99 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Std Specs ORIG
Test was verified on 2/9/2021 ✔