Test 2020-06-19-24-4 (AASHTO T269-14) Summary

Project Information
Project IdentifiersProject ID: 214841
DEA: 034H1004
EFIS: 0318000176
DIST-CO-RTE-PM03-SIE-49-9.2/24.7
Work DescriptionINSTALL RETAINING STRUCTURE AND RSP CONCRETE EMBANKMENT.
Location DescriptionSIERRA COUNTY ON ROUTE 49 AT VARIOUS LOCATIONS
Sample Information
Sample Taken Date6/19/2020 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/22/2020
Sample typeVerification A brief description of the sample3/4" HMA - A
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byChris Last name of sampler or witnessed byHawkins (WITNESS)
Title of samplerVulcan personnel Laboratory sample identificationJMF20-026
The fabricator/manufacturer/facility nameVulcan Materials GVA Transportation Laboratory (TL) Numberc777828
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number JMF Verification ID JMF3513-2021-23
Test Details
DIME Sample ID: 2020-06-19-24
DIME Test ID: 2020-06-19-24-4
Testing Lab: CT D03 - North Region Materials Lab
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2021-02-08
Test Results

Number of tests: 3
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 07/27/2020
Percent Air Voids: 3.8 %
Percent Air Voids 2: 4
Percent Air Voids 3: 4.2
Percent Air Voids Average:4
General comments (publicly viewable) (Max 1000 characters): JMF20-026. Test date estimated.

Test was verified on 02/08/2021