Summary for Test 2020-01-17-15-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/17/2020 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/17/2020
Sample typeQuality Control A brief description of the sampleBin 2 sample pull, initial design
The quantity of what the sample constitutesMultiple Bags, ~40 lbs From where was the sample collectedSource
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byMiltz
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSalinas Asphalt Facility Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-27-0028::HANDLEY RANCH QUARRY
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPulled from Bin 2 drop
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-01-17-15
DIME Test ID: 2020-01-17-15-1
Testing Lab: Granite Construction Company - Coastal
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-02-11

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Ryan Gibbs
Date of test: 01/17/2020
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 79 %
Cumulative percent passing the #8 sieve: 12 %
Cumulative percent passing the #16 sieve: 2 %
Cumulative percent passing the #30 sieve: 1 %
Cumulative percent passing the #50 sieve: 1 %
Cumulative percent passing the #100 sieve: 1 %
Cumulative percent passing the #200 sieve: 0.5 %
General comments (publicly viewable) (Max 1000 characters): Average of multiple bin 2 samples taken over the course of design work to set mix targets

Test was verified on 2/11/2021