Summary for Test 2020-12-03-13-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 212657 DEA: 024G5004 EFIS: 0214000031 |
---|---|
DIST-CO-RTE-PM | 02-TRI-299-1.9-2.3 |
Award Date | 10/01/2019 |
Closeout Date | 11/24/2021 |
Work Description | VIADUCT WIDENING |
Location Description | TRINITY COUNTY NEAR SALYER FROM 0.1 MILE EAST TO 0.6 MILE EAST OF WHITE HOUSE GULCH ROAD |
QA Service Level | 1 (Verified on 09/04/2018) |
Sample Information
Sample Taken Date | 12/03/2020 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/03/2020 |
Sample type | Per Request | A brief description of the sample | Coarse PCC Aggregate |
The quantity of what the sample constitutes | Unknown Quantity | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Colt | Last name of sampler or witnessed by | Sweeny |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78703A | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Eureka Ready Mix | Transportation Laboratory (TL) Number | 897722 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unkown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-12-03-13
DIME Test ID: 2020-12-03-13-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2021-02-05
Test Results
What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 12/04/2020
Cumulative Mass Retained | Cumulative Percent Passing | |||||
---|---|---|---|---|---|---|
10114 grams | ||||||
0 grams | 100 % | |||||
0 grams | 100 % | |||||
1179 grams | 88 % | |||||
6233 grams | 38 % | |||||
8707 grams | 14 % | |||||
9834 grams | 3 % | |||||
10008 grams | 1 % | |||||
10114 grams |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/5/2021 ✔