Test 2020-12-03-13-1 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 212657
DEA: 024G5004
EFIS: 0214000031
DIST-CO-RTE-PM02-TRI-299-1.9-2.3
Work DescriptionVIADUCT WIDENING
Location DescriptionTRINITY COUNTY NEAR SALYER FROM 0.1 MILE EAST TO 0.6 MILE EAST OF WHITE HOUSE GULCH ROAD
Sample Information
Sample Taken Date12/3/2020 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/3/2020
Sample typePer Request A brief description of the sampleCoarse PCC Aggregate
The quantity of what the sample constitutesUnknown Quantity From where was the sample collectedManufacturer
First name of sampler or witnessed byColt Last name of sampler or witnessed bySweeny
Title of sampler Laboratory sample identificationD78703A
The fabricator/manufacturer/facility nameEureka Ready Mix Transportation Laboratory (TL) Number897722
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)Unkown
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2020-12-03-13
DIME Test ID: 2020-12-03-13-1
Testing Lab: CT D02 - North Region Materials Lab
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2021-02-05
Test Results

What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 12/04/2020
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 1179 grams
Cumulative mass retained on the 1/2 in. sieve: 6233 grams
Cumulative mass retained on the 3/8 in. sieve: 8707 grams
Cumulative mass retained on the #4 sieve: 9834 grams
Cumulative mass retained on the #8 sieve: 10008 grams
Cumulative mass retained on the pan: 10114 grams
Mass of all aggregate: 10114 grams
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:88 %
Cumulative percent passing the 1/2 in. sieve:38 %
Cumulative percent passing the 3/8 in. sieve:14 %
Cumulative percent passing the #4 sieve:3 %
Cumulative percent passing the #8 sieve:1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 02/05/2021