Summary for Test 2021-01-30-2-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 213746
DEA: 080Q75U4
EFIS: 0817000114
DIST-CO-RTE-PM08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2
Award Date04/18/2019
Closeout Date06/28/2022
Work DescriptionREPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS
Location DescriptionNot set
QA Service Level1 (Verified on 06/17/2019)

Sample Information

Sample Taken Date01/30/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/03/2021
Sample typeVerification A brief description of the samplePSUE 1/2" RMHA-G-SP 0.50% LAS Aggregate
The quantity of what the sample constitutes5 Bags Coldfeed aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Materials-Corona Drum Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0131G-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials Complany Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0027, 91-33-0073
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number326120 CORD SJR A detailed description of where the material sample was collectedBelt Cut at Vulcan Corona Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-01-30-2
DIME Test ID: 2021-01-30-2-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2021-02-08

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Satish Jain/Sebastian ferrer
Date of test: 02/03/2021
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 98 %
Cumulative percent passing the 3/8 in. sieve: 87 %
Cumulative percent passing the #4 sieve: 42 %
Cumulative percent passing the #8 sieve: 27 %
Cumulative percent passing the #16 sieve: 19 %
Cumulative percent passing the #30 sieve: 13 %
Cumulative percent passing the #50 sieve: 8 %
Cumulative percent passing the #100 sieve: 5 %
Cumulative percent passing the #200 sieve: 3.6 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate Gradation

Test was verified on 2/8/2021