Summary for Test 2021-01-22-1-4

Test performed: CTM 553-1

Project Information

Project IdentifiersProject ID: 213596
DEA: 051C8904
EFIS: 0513000009
DIST-CO-RTE-PM05-MON-101-87.3/R91.5
Award Date12/13/2018
Closeout Date08/23/2023
Work DescriptionPRECAST CONC PVMT, CRACK AND SEAT PAVEMENT AND RECONSTRUCT RAMPS.
Location DescriptionMONTEREY COUNTY IN SALINAS FROM EAST MARKET STREET UNDERCROSSING TO 0.3 MILE SOUTH OF ESPINOSA ROAD
QA Service Level1 (Verified on 01/04/2019)

Sample Information

Sample Taken Date01/22/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/22/2021
Sample typeQuality Assurance A brief description of the sampleRapid Setting Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSupplier
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM214101 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTS Rapid Set Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandCTS
MillJuarez Type of Cementitious MaterialRapid Set Cement

Test Details

DIME Sample ID: 2021-01-22-1
DIME Test ID: 2021-01-22-1-4
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: CTM 553-1: Method for Testing Thermal Stability of Mortar Made with Hydraulic Cement
Test Release Date: 2021-02-09

Test Results


Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 01/29/2021
Average of test specimens broken to nearest 50 kPa, 23 ± 1.7°C for 48h: 39300 kPa
Average of test specimens broken to nearest 50 kPa, 50 ± 1°C for 48h: 36800 kPa
Thermal stability ratio: 94
General comments (publicly viewable) (Max 1000 characters): 3 day test -- Two specimen breaks were outside allowable range per Section 13 of ASTM C109-16. Average compressive strength shown is based on remaining 4 specimens.

Test was verified on 2/9/2021