Summary for Test 2020-12-30-10-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 215421 DEA: 042K9504 EFIS: 0417000057 |
---|---|
DIST-CO-RTE-PM | 04-ALA-580-14.4/14.4 |
Award Date | 02/02/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT MATERIAL TESTING LABORATORY BUILDING. |
Location Description | ALAMEDA COUNTY IN LIVERMORE AT 2201 KITTY HAWK ROAD |
QA Service Level | 1 (Verified on 01/06/2021) |
Sample Information
Sample Taken Date | 12/30/2020 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/06/2021 |
Sample type | Per Request | A brief description of the sample | soil |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | D | Last name of sampler or witnessed by | Nesbitt |
Title of sampler | Transportation Engineer | Telephone number of sampler | 510-622-0104 |
Laboratory sample identification | CR20210002 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | C969977 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | 04-2K950 | Structure unique identifier | 04-ALA-580 PM14.3 |
Structure name | D4 Mat Lab |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | RW-20-001 |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Corrosion Testing | A detailed description of where the material sample was collected | 5-10 feet depth |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2020-12-30-10
DIME Test ID: 2020-12-30-10-1
Testing Lab: Wood
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2021-02-22
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Tim Steele
Date of test: 01/18/2021
Minimum soil resistance of the lab measurement: 900 Ohms
Soil sample temperature: 17.8 C
Soil box constant: 1
pH of soil: 8.10
Minimum soil resistance corrected to 15.5: 951.75 Ohm-cm
Minimum soil resistivity at 15.5: 951.75 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/22/2021 ✔