Summary for Test 2015-04-16-5-2
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 7409 DEA: 07245403 EFIS: 0700000431 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-31.1/32.3 |
Award Date | 02/29/2012 |
Closeout Date | 10/27/2016 |
Work Description | Construct Connector between I-10 and I-605 (Design Build Project) LA-10-31.1/32.3, LA-605-R20.2/20.6 |
Location Description | 10 & 605 IC |
QA Service Level | 1 (Verified on 03/14/2013) |
Sample Information
Sample Taken Date | 04/16/2015 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/20/2015 |
Sample type | Quality Control | A brief description of the sample | Concrete Cylinders |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Oscar | Last name of sampler or witnessed by | Rodriguez |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | site | Transportation Laboratory (TL) Number | 60516 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | s75099 |
---|---|---|---|
The truck number from where the sample was collected | 395 | The batch plant ticket number from where the sample was collected | 199334 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | frame 3 soffit and stem Pour1 spans 11 and 10 | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-04-16-5
DIME Test ID: 2015-04-16-5-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-05-28
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 05/28/2015
Average diameter of cylinder 1: 6 in
Average diameter of cylinder 2: 6 in
Maximum load on cylinder 1: 169690 lb
Maximum load on cylinder 2: 164980 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 42 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 6002.5 psi
Compressive strength of cylinder 2: 5835.9 psi
Compressive strength (to nearest 10 psi): 5920 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/28/2015 ✔