Test 2021-01-14-20-5 (AASHTO T96-02r10) Summary

Project Information
Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
Sample Information
Sample Taken Date1/14/2021 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/22/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R15 0.5% LAS
The quantity of what the sample constitutes2 Bags Belt Cut Aggregate 1 Bag Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byDevin Last name of sampler or witnessed byFuerty G3
Title of sampler Laboratory sample identification0118A-21
The fabricator/manufacturer/facility nameVulcan-Corona Drum Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit) 91-33-0027, 91-33-0073
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number224112 CORD SJR A detailed description of where the material sample was collectedBelt Cut at Vulcan Corona Drum
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-01-14-20
DIME Test ID: 2021-01-14-20-5
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2021-01-28
Test Results

Input Type: Measured
Tester's full name: Sebastian Ferrer
Date of test: 01/26/2021
Grading designation: C
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4802 grams
Mass of sample on No.12 sieve (after 500 revolutions): 4055 grams
Percent loss after 100 revolutions:4 %
Percent loss after 500 revolutions:19 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 01/28/2021