Test 2020-12-14-27-8 (AASHTO T315-16) Summary

Project Information
Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date12/14/2020 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/25/2021
Sample typeVerification A brief description of the sampleCOC Sample
The quantity of what the sample constitutes1 of 3 cans Multi-Grade PG64-16/10 From where was the sample collectedManufacturer
First name of sampler or witnessed byDon Last name of sampler or witnessed byPowell
Title of sampler Laboratory sample identification20641641
The fabricator/manufacturer/facility nameSan Joaquin Refining Co Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number32001
Time of sample HMA SupplierNot set
Asphalt Binder SupplierNot set MultigradeNot set
JMF Verification ID
Test Details
DIME Sample ID: 2020-12-14-27
DIME Test ID: 2020-12-14-27-8
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-01-27
Test Results

Phase: RTFO residue
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 01/27/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.228 kPa
Phase Angle (δ) (for the 10 cycles): 88.5 degree
Complex Modulus (G*) (for the 10 measurements): 2.282 kPa
Test Temperature: 64.0 C
Dynamic Shear, G*/sin(δ): 2.28 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 01/27/2021