Test 2020-07-24-53-4 (AASHTO T304-11) Summary

Project Information
Project IdentifiersProject ID: 214618
DEA: 033F99U4
EFIS: 0319000311
DIST-CO-RTE-PM03-SUT-99-39.2/41.4
Work DescriptionWIDEN RDWY, HMA, CRCP, WATER LINE, SIGNALS, & LIGHTING SYSTEM.
Location DescriptionSUTTER COUNTY IN AND NEAR LIVE OAK FROM 0.1 MILE SOUTH OF COLEMAN AVENUE TO NEVADA STREET (NORTH INTERSECTION)
Sample Information
Sample Taken Date7/24/2020 Sample Unique Key53
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/27/2020
Sample typeVerification A brief description of the sample3/4" HMA-A w/RAP
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byBrad (WITNESS) Last name of sampler or witnessed byMckeehan (WITNESS)
Title of samplerDGS Personnel Laboratory sample identificationJMF20-029
The fabricator/manufacturer/facility nameDeSilva Gates Aggregates-Marysville Transportation Laboratory (TL) Numberc779826
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-58-0011
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID JMF3513-2021-8
Test Details
DIME Sample ID: 2020-07-24-53
DIME Test ID: 2020-07-24-53-4
Testing Lab: CT D03 - North Region Materials Lab
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-01-26
Test Results

What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Thomas Stinnett
Date of test: 07/29/2020
Bulk dry specific gravity: 2.655
Average uncompacted voids:46.9 %
General comments (publicly viewable) (Max 1000 characters): JMF20-029. Test date estimated. Thomas Stinnett

Test was verified on 01/26/2021